Member Information and Posts by blackstoneboy
from the Newbies department...
Reactive Power, reactive load, voltage
Topic: Power generation equipment control.
Posted by blackstoneboy on 14 November, 2009 - 12:34 am
Got few questions in regards with Reactive Power, Reactive Load, voltage and power factor
from the Newbies department...
Delta Corner Grounded Transformer
Topic: Engineering and workplace issues.
Originally posted by Blackstoneboy on 6 November, 2009 - 10:41 pm
No fault occurence on delta corner grounded transformer.
New Replies:
Dear Phil, In regards with your reply, i have seen and read the thread but i am still confused....
from the EE department...
pf control
Topic: Power generation equipment control.
Originally posted by eurydice on 5 November, 2009 - 10:44 pm
AVR control of islanded systems
New Replies:
Try to check the basics of Real power, apparent power, and reactive power. If the power factor of...
from the Newbies department...
NGR in Generator Synchronizing
Topic: Engineering and workplace issues.
Originally posted by Blackstoneboy on 10 October, 2009 - 11:58 pm
How should NGRs be connected during paralleling of generators??
New Replies:
Dear Phil, Analyzing the circuit, if the two NGRs are connected when the generators are in...
from the synchronizing noob department...
Earth Fault on System
Topic: Power generation equipment control.
Posted by blackstoneboy on 2 March, 2009 - 4:15 am
Earth Fault Detected on system
from the Synch Noobs department...
Instrument Transformers For Synchronizing
Topic: Power generation equipment control.
Originally posted by blackstoneboy on 4 February, 2009 - 3:33 am
Instrument transformer to be used
New Replies:
If it does have phase shifts, how can we guarantee the accuracy our system using these instrument...
The system voltage of the generators is 13.8kv, while the utility is 34.5kv.. The power transformer...
from the Customer Service department...
How to Control Earth Voltage - Neutral-Earth
Topic: Information resources, documentation.
Originally posted by Omar Saeed on 2 February, 2009 - 7:20 am
How to controll earth voltage i.e. Neutral-Earth voltage
New Replies:
I suggest add another ground pit until you have a voltage less than your required. place the...
from the Production department...
Generator Frequency
Topic: Power generation equipment control.
Originally posted by surameen on 25 January, 2009 - 5:31 am
What type of excitation can be used?
New Replies:
what kind of generator is that?? If it is the generator,, it cant have a frequency of that kind....
from the ELECTRICAL department...
PT open delta/Star connection
Topic: Power generation equipment control.
Originally posted by MEHMOOD on 21 January, 2009 - 5:43 am
PT connection (protection side)
New Replies:
Is the term earthing same as neutral? If so, where should we connect it? If we are going to...
from the Bean Counter department...
Power Factor Correction
Topic: Application Questions and Problems
Originally posted by Kevin on 24 September, 2008 - 5:05 pm
Power Factor Correction
New Replies:
Try to calculate the power using the basic equation P= 1.732xIVxp.f Suppose you have a power...
from the Operations department...
Excitation Voltage
Topic: Engineering and workplace issues.
Originally posted by vassy on 17 January, 2009 - 11:51 am
When we increase excitation voltage, Gen. terminal voltage also increases...
New Replies:
If we increase the excitation voltage, the generator terminal voltage will also increase because we...
from the Forum department...
Three Questions about Diesel Generator
Topic: Power generation equipment control.
Originally posted by azman on 16 January, 2009 - 11:09 pm
Any possibility to test run synchronizing without load?
New Replies:
Sir, 1. Yes it is really possible to do synchronization without load. I agree with CSA that you...
from the Synchronizing Class department...
Cause of reverse power
Topic: Power generation equipment control.
Posted by blackstoneboy on 15 January, 2009 - 8:33 am
Cause of reverse power.
Topic: Power generation equipment control.
Originally posted by Blackstoneboy on 13 January, 2009 - 12:27 am
Can anyone explain to me what is the effect of closing the generator circuit breaker of which genset is not yet in phase with the synchronizing bus?
New Replies:
Is it the same as having a line to line fault?? Just like having a three phase system and each line...
from the Automation department...
SCADA setup
Topic: Human-Machine Interface and SCADA.
Originally posted by Jan Michael on 11 January, 2009 - 9:15 pm
How can I set up my SCADA system using Allen-Bradley? Can I have a definition and list of hardware and software that is necessary?

New Replies:
Yes, you can set up your SCADA using AB PLC. Can you give me the list of equipment you have for...
from the Forum department...
Loadbank Resistors
Topic: Power generation equipment control.
Posted by blackstoneboy on 2 November, 2008 - 8:54 pm
Can the loadbank resistors operate at different voltages?
1
 
 
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2009 Nerds in Control, LLC. All rights reserved.