Topic: Power generation equipment control.
from the operations department...
shaft voltage test
Originally posted by pawan on 12 January, 2012 - 9:56 am
shaft voltage test for gas turbine
New Replies:
Hi RK, I am not aware which exactly voltage readings and which current readings are used by...
Hi pawan, Speedtronic (MKV and MKVI) gives two ways to check integrity of the shaft voltage...
Topic: Power generation equipment control.
from the Forum department...
HMI Data display problem
Originally posted by ESKAY on 5 February, 2012 - 5:10 am
Under Motor status display page, the status of Dc Emergency lube oil pump running is not shown in the status target display.
New Replies:
Hi, On GE HMI with Cimplicity, the text and/or color of the dynamic filed is setup on the 'Color...
Originally posted by RP on 10 February, 2012 - 11:05 pm
ARCNET COMMUNICATION LOSS TO <I> PROCESSORS IN A NETWORK OF <I>, AFTER DCC ERROR ACCUMULATION AND QST DPM TIME OUT MESSAGES IN <C> PROCESSOR
New Replies:
> (iii) What could be the reason for the buffer full message "DCC unable to get > DPM...
Topic: Power generation equipment control.
from the Forum department...
MARK-V
Originally posted by ALI on 3 February, 2012 - 10:00 am
Gas Turbine Load/IGV hunting at 75 to 85MW in winter.
New Replies:
Hi, I assumed that your statement: 'cold weather' refers to temperatures below neg 20 degC not...
> Hunting is only observed during cold weather i.e temp. <20deg C. load between 75MW and...
Topic: Power generation equipment control.
from the Instrument and control department...
mark vi, VCMI dignostic alarm
Originally posted by uj on 4 February, 2012 - 2:48 am
VCMI card having diagnostic alarm - "GCV NOT FOLLOWING REF. TRIP"
New Replies:
Hi, On TMR control system, even serious defect on one processor should not trip the turbine. So...
Topic: Power generation equipment control.
from the Instrument Lover department...
TBQD card problem in S processor
Originally posted by prasath on 31 January, 2012 - 9:49 am
Problem in TBQD card in S processor in Mark-v
New Replies:
Hi, There are fuses on power supplying cards TCPS, on processors (R/S/T/C). Please check...
Hi, Please consult Application Manual GEH 6195 Appendix D for details of connections in MKV. ...
Topic: Communications systems and equipment.
from the c&I maintenence department...
Mark-v control system
Originally posted by hiten on 29 January, 2012 - 1:33 pm
how does denet work in mark-v?
New Replies:
Hi, To trace internal MKV connections you have to refer to GE drawings: 'Case wiring', provided...
Topic: Power generation equipment control.
from the Mechanical department...
combustion dynamics in gas turbine
Originally posted by bhola on 24 June, 2010 - 7:41 am
combustion dynamics in gas turbine
New Replies:
Hi, Additional information provided by you suggests, as stated by GE in your message, for...
Hi, You did not tell which turbine model you have. On Frame 9FA with DLN2+system dynamics...
Topic: Power generation equipment control.
from the Forum department...
Frame 6B Spread problem
Originally posted by jv on 27 January, 2012 - 6:00 pm
After HGPI our GT exhaust temperature is too high between 25-37MW
New Replies:
Hi JV and Sardar9, As you write TCs were inspected. You did not tell how the thermocouple...
Topic: Power generation equipment control.
from the power plant I&C department department...
Mark V - Define the new Scale Type
Originally posted by ControlCrazySean on 27 January, 2012 - 2:29 am
How do you define the new scale type?
New Replies:
Hi, On MKV with HMI, scledata.dat file exists but is not used because here TCI manages scaling...
Topic: Power generation equipment control.
from the Forum department...
power generation
Originally posted by ESKAY on 18 January, 2012 - 3:47 am
ctif-1 and ctif-2 readings disagree alarm and latching.
New Replies:
Hi, Did you verify the supplying voltage to MKVI: voltage level, voltage unbalance v.s. ground,...
> Kindly explain the reasons for this effect on LOAD and FPG low Pressure > alarm. And what...
Topic: Power generation equipment control.
from the Operation department...
Gas turbine 7FA DLN2.6 Start Counter
Originally posted by KKK on 21 January, 2012 - 10:03 am
difference between "Total starts counter" and "manually initiated starts counter"
New Replies:
Hi, Below description was prepared based on the standard code. Please check the code on your...
Topic: Power generation equipment control.
from the instrument and control department...
Wobbe index alarm and unit trip
Originally posted by mohamed salem on 8 January, 2012 - 2:07 pm
wobbe index alarm
New Replies:
> but it is not clear if this runback give command to D5 to > cut in or not please if u have...
Dear Sir, Please confirm with code on your site: when wobbie index alarm is present you loose...
Hi Mohamed, Origin of the alarm you mentioned is in most cases too low gas temperature. Burning...
Topic: Power generation equipment control.
from the Reduced Current department...
Reduced Gas Turbine Power Output
Originally posted by Kyle Gardner on 11 January, 2012 - 7:12 am
Troubleshooting reduced power output in GE Frame 6 Gas Turbine Generator
New Replies:
> "We applied known calibration gas pressure to the CPD sensing line and > verified...
> Mass Flow is not up or down but the CPD is definitely an issue... calibrated it also last...
Topic: Power generation equipment control.
from the Power plant instrument Technician department...
Mark V constant adjust
Originally posted by Chawki on 15 January, 2012 - 5:20 am
Adjusting control constants for Mark V
New Replies:
Hi, Thanks for feedback. Very clever solution. Remains open the question how the problem...
Hi, - Is this Simplex or TMR MKV? - Do you have any diagnostic alarms? - Are all...
> in our control constant, there is a ? sign in the beginning of the line and > could not...
Topic: Power generation equipment control.
from the Maintenance department...
Mark V <C> core problem
Originally posted by saha on 15 January, 2012 - 11:17 am
Mark V <C> core problem
New Replies:
> I have changed all the <C> core cards TCCA, SDCC, SLCC, TCDA and the power > supply...
Topic: Power generation equipment control.
from the Forum department...
Cooldown GT GE MS9001
Originally posted by tukanginsinyur on 6 January, 2012 - 1:02 am
Questions on cooldown GT GE MS9001
New Replies:
Tukanginsinyur, The details of the cooldown process after turbine shut down and before start up...
Select Page: 1
 
 

Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2013 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.


Fortune
Mitchell's Law of Committees:
Any simple problem can be made insoluble if enough meetings are
held to discuss it.
Advertise here
Advertisement
our advertisers
Help keep our servers running...
Patronize our advertisers!
Visit our Post Archive