Member Information and Posts by girish_prajapati55from the power department...
logics related to emergency lube oil pump , auxiliary lube oil pump & turning gear motorexplain the logics related to auxiliary lube oil pump, emergency lube oil pump & turning gear motor for gas turbine
Which transformers work best with star and delta connections
Which bases it is decided to trip gas or steam turbine or only generator should trip on the occurrence of fault
WHAT IS THE FUNCTION OF THE VERSAMAX MODULE IN EX2100 PANEL.
What is the relation between grid frequency variation & plant load?
EACH GT HAS TWO BATTERY CHARGER (2*100%) TO FEED EMERGENCY SUPPLY TO AUXILIARIES. What if BOTH BATTERY CHARGER FAILS when GTG RUNNING?
What will happen if anybody by mistake switch off mark-6 power supply, when gas turbine generator running normal?
from the Electrical operation department...
GT MCC module has 240 V AC control supply and 125 V DC indication supplyI am working in CPP with 750 MW power generation capacity. There are 6 gas turbine generators. GT MCC of all the generators has 240 V AC for control circuit and 125 V DC for indication circuit...
from the Electrical operation department...
Difference between overvoltage and over excitation protection given to generatorI am working in CPP with 750 MW power generation capacity. There are 6 gas turbine generators. Generators have both overvoltage and overexcitation protection...
In our CPP, there are 6 GTs (124 MW each). A few days before we were going to start up the gas turbines, suddenly flame came out from the GT exhaust.
How and when does the static switch operate in inverter?
from the electrical executive department...
Explanation about 59TEX (generator excitation transformer homopolar voltage supervision)Please explain about 59TEX (generator excitation transformer homopolar voltage supervision) protection applied to generator & excitation system.
1
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2009 Nerds in Control, LLC. All rights reserved.