Topic: Power generation equipment control.
from the Operation department...
Compressor fouling
Posted by Fai on 20 May, 2013 - 9:31 pm
CPD reduced CTDA remain at low temperature. Baseload was reducing as well
Originally posted by Nsikan Williams on 20 May, 2013 - 4:27 pm
just inherited a new plant without adequate handover documentation. just need some info guys.
New Replies:
Dear Nsikan, For my site (frame 9FA), GE setpoint for inlet air filter dp alarm are 4inch H20...
Topic: Power generation equipment control.
from the Operation department...
Turbine Exhaust Pressure
Originally posted by Fai on 5 September, 2012 - 3:27 am
Causes and Effects in rising of Turbine Exhaust Pressure
New Replies:
Dear Sir, Thanks for the prompt respond. I've trend the steam generation and found that the steam...
Topic: Power generation equipment control.
from the Gas turbines department...
Compressor discharge temperature
Originally posted by Harish on 10 May, 2012 - 6:36 am
Is there a way to calculate the compressor discharge temperature of a gas turbine without the use of compressor efficiency?
New Replies:
try the formula as per below T2/T1 = (P2/P1)^(k-1/k) where k = 1.4 T1 = ambient temp P2 =...
Topic: Power generation equipment control.
from the operation department...
BOILER DRUM LEVEL GLASS ISOLATION VALVE
Originally posted by M.S. KALEEM on 6 December, 2011 - 9:39 am
TELL ME WHY BOILER DRUM LEVEL GLASS ISOLATION VALVES ARE OPPOSITE IN DIRECTION?
New Replies:
This is because when the boiler drum may vibrates during in operation. the handle might moves down...
Topic: Power generation equipment control.
from the Operation department...
Compressor Discharge Temperature
Originally posted by fai on 16 November, 2011 - 9:56 pm
Compressor discharge temperature only slight increase after compressor blades fouled
New Replies:
Thanks CSA for your reply. Over the years since 2007, I have keep all the trending related to...
Topic: Power generation equipment control.
from the Operation department...
FSRT control
Posted by fai on 6 September, 2011 - 10:05 pm
How's FSRT is calculated? Why sometimes the FSRT value is different during different days of machine on Baseload.
Topic: Power generation equipment control.
from the Operations department...
Condenser Make up calculation
Originally posted by Rokan Uddin on 20 August, 2011 - 9:25 am
How can condenser make up be calculated?
New Replies:
Dear Rokan, Sorry for the late reply as I was away from plant for few weeks. I've sent you the...
if you have a PI system (Data Historian), I have done a simple excel file to calculate the demin...
Topic: Power generation equipment control.
from the Operation department...
Lube oil system
Posted by Fai on 22 July, 2011 - 3:55 am
Lube oil strainer in return piping location
Topic: Power generation equipment control.
from the Operations department...
Gas Manifold Temperature
Originally posted by Fai on 7 June, 2011 - 10:43 pm
What differences it would make if PTG1 (G1 Manifold Temperature) reduced or increased during Unit on baseload?
New Replies:
Dear CSA, Thanks for the reply, May I know what can cause this PTG1 temperature to increase or...
Topic: Power generation equipment control.
from the operations department...
gas turbine water wash
Originally posted by laxman on 15 May, 2011 - 12:33 pm
hi i am working in GE BASED power plant i want know why we have to reduce GT load at the time of online water wash OF COMPRESSOR
New Replies:
you'll gain extra few MW during online water wash during unit at BASELOAD. it just like power...
Topic: Power generation equipment control.
from the Private department...
Foreign object damage on compressor
Originally posted by Mark on 12 May, 2011 - 2:04 am
Looking for description of Foreign object damage on compressor
New Replies:
Hi Mark, Did you done any power argumentation regularly during GT on BASELOAD? any sign of...
Topic: Power generation equipment control.
from the operation department...
Back up temperature curve activate
Posted by Fai on 29 April, 2011 - 3:46 am
Why Temperature Backup Curve activated?
Topic: Power generation equipment control.
from the Operation department...
Compressor Blow Off Valve
Posted by fai on 21 April, 2011 - 4:03 am
How to check compressor Blow Off Valve
Topic: Power generation equipment control.
from the Operation department...
GT Power reduce
Originally posted by Fai on 18 March, 2011 - 5:05 am
GT Power unrecoverable after Compressor Offline Washing. Compressor isentropic efficiency is at optimum setpoint but not for GT output power
New Replies:
Dear CSA, We did our MI (Major Inspection on Jan 2010), that time we found cracks on our rotor (GT...
Topic: Power generation equipment control.
from the Operation department...
ST BB3X vibration high
Originally posted by Fai on 17 March, 2011 - 5:23 am
ST BB3X vibration goes high after Major Inspection from 0.07mm/s now at 0.18mm/s
New Replies:
Thank you for the reply, I'll have a look into that TIL 1583. ...
Select Page: 1
 
 

Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2013 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.


Fortune
Love at first sight is one of the greatest labor-saving devices the
world has ever seen.
Advertise here
Advertisement
our advertisers
Help keep our servers running...
Patronize our advertisers!
Visit our Post Archive