Topic: Power generation equipment control.
from the Maintenance department...
Frame 6B Lube Oil Heaters
Originally posted by davidmcc on 21 May, 2013 - 3:52 am
Where are the lube oil heaters located?
New Replies:
Thanks CSA, you're right, the lube oil heater 23QT-1 is accessible at low level on the side of...
Our three are on the right side of the oil tank. There is a TIL on these, talks about reconfiguring...
Topic: Power generation equipment control.
from the instrumentation department...
servo regulator
Posted by vm on 22 May, 2013 - 1:33 am
What is meant integrator convergence gain for servo regulator?
Topic: PLCs and related questions.
from the For a book department...
PLC's with free programming software?
Originally posted by Mark Wills on 14 October, 2006 - 6:21 pm
Looking for PLC's that can be programmed in Ladder, FBD and Structured text, preferably with free, or low cost programming software.
New Replies:
micrologix 1100 has free lite version software...
Topic: Communications systems and equipment.
from the Forum department...
Mobus slave Address
Posted by UY on 21 May, 2013 - 9:42 pm
About modbus protocol
Topic: Power generation equipment control.
from the Forum department...
Cimplicity configuration
Posted by Abdou on 21 May, 2013 - 4:01 pm
HMI upgrade
Topic: Power generation equipment control.
from the Instrumentation department...
Ratchet problem
Originally posted by vijay on 19 May, 2013 - 10:40 am
we had a problem in the ratchet mechanism
New Replies:
Experience ratchet pump both AC and DC pump cut-in during ratcheting operation. Found motor pump...
By Venkatachalam, Valliappan X on 20 May, 2013 - 12:11 am -
In my experience, we faced similar problem in one of the turbines where the ratcheting was...
Topic: Software, including programming, OS issues, etc.
from the Maintenance department...
LIquid Fuel Bypass Valve Mark V Flame 5 (MS5001)
Posted by STEVEN on 21 May, 2013 - 12:31 pm
Load running at limitation when running on fuel oil.
Topic: Communications systems and equipment.
from the Forum department...
Polling a Modbus Slave
Originally posted by JBB on 19 May, 2013 - 1:42 pm
Setting up communication for Modbus Polling
New Replies:
Hello, Try use the Modbus Tester from www.modbus.pl to check what errors you have. Regards, ...
By William \(Bill\) L Mostia Jr PE on 19 May, 2013 - 9:30 pm -
What error did you get? William (Bill) L. Mostia, Jr. PE Fellow SIS-TECH Solutions, LP Any...
Sounds like either your master or your slave doesn't want to return more than 50 registers at a...
Posted by Akhtar on 21 May, 2013 - 8:17 am
If the water injection pump trips, what will happen to GT exhaust temperature?
Topic: Software, including programming, OS issues, etc.
from the Instrumentation department...
AS160OS (Fix32) Configuration Problem
Originally posted by Sukhdev Singh on 17 May, 2013 - 9:06 am
ABB "OS Loader" Configuration Problem
New Replies:
Sounds like you have faulty installation disks. You could be completely out of luck here unless...
Topic: Power generation equipment control.
from the Forum department...
Frame 6B Exhausrt Temperature Spreads
Originally posted by James Murray on 14 January, 2013 - 7:53 pm
FR6B tripping on Exhaust Temp spreads at FSNL
New Replies:
We had sort of the same problem once. We had lost the diffuser off our compressor bleed valve...
Posted by Nsikan Williams on 20 May, 2013 - 4:27 pm
just inherited a new plant without adequate handover documentation. just need some info guys.
Topic: Software, including programming, OS issues, etc.
from the Software department...
Modbus data swapping issue
Originally posted by Anshuman on 20 May, 2013 - 12:18 am
Data is swapped when same ID, function code and no of registers are polled.
New Replies:
By Lynn August Linse on 20 May, 2013 - 1:38 pm -
This is a common issue in "packet switched" radio systems, because the radios do retries...
It sounds like you have a synchronization issue, which can occur if you have a "dead"...
Hello, Yes, this is a known issue with MODBUS. I had a slave device once that on occasion...
Topic: PLCs and related questions.
from the Automation department...
GE 90-30 series COMM_REQ slowing down data usage
Originally posted by Suraj Shetty on 19 May, 2013 - 1:06 pm
Slow down communication between GE 90-30PLC which are using COMM_REQ SRTP channel commands. and these are communicating over ethernet through cellular modems. the data plan on the cellular modem has a limit of 5GB only.
New Replies:
There is more information on this here: http://www.plctalk.net/qanda/showthread.php?t=79691 (Be...
Maybe a counter in the sending rung so it sends every other scan or less. I could be way off I...
Originally posted by Anonymous on 3 December, 2005 - 6:29 pm
what kind of electrical CAD software is most used by you guys?
New Replies:
I agree that CADS Planner Electric is smart choice for electrical and automation design. it also...
Topic: Power generation equipment control.
from the Forum department...
servo valve calibration
Originally posted by ESKAY on 19 May, 2013 - 4:16 pm
Distillate fuel servo calibration
New Replies:
It's difficult I know, really the only way to check is do a "dummy fire" with no spark...
Topic: Power generation equipment control.
from the Operations department...
Loss of MW's after outage
Originally posted by MD on 19 May, 2013 - 4:52 pm
Loss of MW's coming out CI
New Replies:
1) What do you mean by "loss of air flow", can you explain more? 2) Do you have data...
Topic: Continuous process industries, DCS questions.
from the Design department...
RS232C to MODBUS Interface
Originally posted by Anand on 18 May, 2013 - 3:44 pm
Request for help related to appropriate hardware-software interface
New Replies:
You need to provide a couple more bits of information to clarify. RS232 and Modbus aren't mutually...
Topic: PLCs and related questions.
from the serious department...
Mark VI - VCMI Board Replacement
Originally posted by Fausto on 23 February, 2010 - 9:59 am
Mark VI not working with a VCMI board replacement!!
New Replies:
Salem have acknowledged problems with IS215VCMIH#B and H#C. The issue is with socketed IONET...
Topic: Power generation equipment control.
from the control department...
GT FSR for warm up the turbine
Originally posted by Ahmed on 31 January, 2013 - 12:32 pm
FSR fuel reference - margin of FSR warm up
New Replies:
Unfortunately the next opportunity will be in a year so I am trying to compile notes and make a...
CSA, I appreciate the reply. There is a general feeling among the operators and mechanical...
Topic: PLCs and related questions.
from the Forum department...
Communications between Quantum PLCs
Originally posted by tania on 16 May, 2013 - 8:06 pm
Quantum PLC Communications
New Replies:
With 2 quantums you map index will be 0. its like an offset setting. your slot ID will be 254 if...
Originally posted by Fyzal on 16 May, 2013 - 6:53 am
Low output after smoke coming out from the extraction pipe from bearing #2
New Replies:
Fyzal, Lube oil header temperature is quite higher, I think that it should be in 50~55C, try to...
Topic: Power generation equipment control.
from the operation department...
hydraulic filter
Originally posted by P.P.Salim on 18 May, 2013 - 4:01 am
How to change over Hydraulic oil filter in frame6B GE gas turbine, while the Gas turbine is in service.
New Replies:
Check your P & ID for details. 1)open the fill valve and allow stand-by filter to be full...
Originally posted by Ben on 16 May, 2013 - 5:32 pm
Several steps of external resistance used for speed control on motor appear to have uneven amounts of resistance. Is this possible? What will the effect on the motor be?
New Replies:
Phil, Again appreciate your valued comments. It's people like yourself that keep the world...
Phil, Really appreciate your response. Unfortunately all i've got is a really poor wiring /...
Topic: Motion control, servos, steppers, etc.
from the mechanical design department...
control of servovalve
Posted by george on 18 May, 2013 - 3:26 pm
synchronization of 2 servo valves that control 2 cylinders
Topic: PLCs and related questions.
from the Instrumentation department...
gefanuc 9030 modules
Originally posted by amirqadri on 17 May, 2013 - 2:22 pm
IC693MDL module not giving output after programming.
New Replies:
Output modules are typically powered with an 'outside' source independent of the PLC. If the output...
Topic: Power generation equipment control.
from the Operations Department department...
Mark VI IONet N-Tron Network switch failures
Originally posted by D.V on 2 November, 2011 - 6:24 am
Mark VI IONet N-Tron Network switches keep on failing, RCA needed
New Replies:
We too are facing a lot of failures in N-tron switches (516/508 Fx and tx). After an RCA by N-tron,...
Posted by Jhon on 17 May, 2013 - 2:00 am
What is the critical speed of Centaur 40?
Topic: PLCs and related questions.
from the DCS Interface department...
Ovation Serial Interface to Control Logix
Originally posted by Ann Roberts on 14 May, 2009 - 3:33 pm
Serial interface between Allen Bradley's Control Logix and Emerson Ovation DCS
New Replies:
Ann, how about the Nexus1250 its provided with RS485 communication port that could support A...
Topic: Power generation equipment control.
from the Gas Turbine Control department...
FSRMIN / Acceleration confusion
Posted by MWO on 16 May, 2013 - 10:06 pm
Very confused about the operation of minimum FSR/Acceleration Control and their constants. (probably too many questions on one posting)
Topic: Communications systems and equipment.
from the Maint/Ops department...
Modbus Comms between 2 devices
Posted by Fox on 16 May, 2013 - 9:25 pm
New to Modbus, trying setup communication between two devices.
Topic: Power generation equipment control.
from the Forum department...
Woodward 505 steam controller
Posted by Mick on 16 May, 2013 - 5:29 pm
Woodward 505 steam controller Alarm issue
Select Page: 1 2 3 4 5 6 7 8 9 10 11 Next
 
 

Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2013 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.


Fortune
The easiest way to figure the cost of living is to take your income and
add ten percent.
Advertise here
Advertisement
our advertisers
Help keep our servers running...
Patronize our advertisers!
Visit our Post Archive