Select Page: 1
Control.com member...
Member Information and Posts by ore_rotundo
Topic: Engineering and workplace issues.
from the Engineering department...
Turbine Vibrations
Originally posted by Prabhakar1949 on 13 June, 2009 - 12:44 pm
Reasons for high vibrations in turbines
New Replies:
Usually GT bearings are equipped with radial, axial and seismic vibration probes. Standard GE HD...
Topic: Power generation equipment control.
from the Instrument And Control department...
GE Frame VI Gas Turbine Ignition trouble
Originally posted by Jatin on 30 April, 2009 - 7:38 am
GE Frame VI gas Turbine starting ignition problem
New Replies:
Jatin, No problem, now we know a bit more about your GT. So you found spark plug of...
Jatin, Interesting problem. hope is not the solution… We are missing some relevant information...
Topic: Power generation equipment control.
from the Forum department...
Gas Turbine High Exhaust Temperature Trip
Originally posted by Gunga Chea on 17 April, 2009 - 2:37 am
Gas Turbine trips on High Exhaust Temperature minutes after starting.
New Replies:
Gunga, You have got a lot of useful replies from the community. Probably you are too busy to...
Topic: Continuous process industries, DCS questions.
from the Forum department...
turbine performance
Originally posted by dmi on 7 April, 2009 - 2:42 am
turbine performance reduced
New Replies:
dmi, Without giving the application type of the turbo compressor such as, for midstream,...
Topic: Power generation equipment control.
from the Forum department...
firing temperature calculation
Originally posted by sheila on 17 March, 2009 - 6:20 am
GE gas turbine firing temperature calculation
New Replies:
Sheila, I am not sure, what is your main driver behind your original question. Why would like to...
Topic: Power generation equipment control.
from the Maintenance department...
Replace Mark 5 by Mark 6
Originally posted by DAMENE Amar on 25 March, 2009 - 8:30 am
It is neccessary to replace Mark 5 by Mark 6
New Replies:
Previous discussed issues for control system upgrade, refer to thread below. Docendo Discumus ...
Originally posted by Serg on 21 March, 2009 - 4:31 pm
translating SPEEDTRONIC Mark VIe Turbine Control Systems Guide...
New Replies:
Hello over there, The wind up (P2 check) you are describing is not used in older control system...
Topic: Application Questions and Problems
from the control department...
MarkVI Simplex project software
Originally posted by power plant on 18 January, 2008 - 11:26 pm
looking for any MarkVI Simplex project software for gas turbine GE5001 power generation that work on dual fuel light & heavy fuel
New Replies:
Jaffar, TECHNICAL ISSUE TO THINK ABOUT? Is this upgrade from MK5 to MKVI or MKII to MKVI? If...
Interesting story. I dont think that GE will give you only the hardware without the software. Did...
Topic: Continuous process industries, DCS questions.
from the Design department...
Centrifugal compressor control
Originally posted by Raj on 21 March, 2009 - 12:39 pm
Why does centrifugal compressor pressure is controlled in suction through inlet guide Vanes?
New Replies:
Hi Raj, Depending on the used compressor control algorithm, it may vary the application of the...
Topic: Power generation equipment control.
from the Out of "Controls" Group department...
Electrical VS Mechanical Overspeed
Originally posted by MIKEVI on 19 March, 2009 - 1:04 pm
Compare mechanical overspeed to "electrical" overspeed.
New Replies:
I will suggest before inventing something, maybe you should review the modification reports during...
Topic: Application Questions and Problems
from the Maintenance department...
SERVO VALVE NULL Bias Current
Originally posted by saha on 24 February, 2009 - 11:06 am
SERVO VALVE NULL Bias Current
New Replies:
Hombre, This is not football, it look like that we are ping ponging Now get back reality. ...
Dear Servo 2001 Maybe its good to highlight that, we are not fundamentally promoting the OEM's...
Select Page: 1
 
 

Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2014 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.


Fortune
If it's Tuesday, this must be someone else's fortune.
Advertise here
Advertisement
our advertisers
Help keep our servers running...
Patronize our advertisers!
Visit our Post Archive