New Replies:
The logic of the process people is correct. however i am not able to understand why only this...
from the Control And Instrumentation department...
Woodward 505 Governor did not switch over during grid failureduring grid failure our generator automatically was not switch over to frequency control mode to load control mode - woodward 505 governor.
New Replies:
Dear Amit,
The normal phenomenon is when you are parallel with grid the unit will be operated in...
load Fluctuation on Steam turbine generators
New Replies:
What happened to the problem? whether it is solved any clue you got. please mention the forum for...
Looking in to the trends especially of control oil pressure, there should not be so much...
The question put by CSA is very relevant, i.e. the load condition of GTs during load fluctuations...
CFBC Water wall tube erosion in kick off zone
causes of Steel chimney corrosion and remedial actions for the same
Load shedding by PCS7
New Replies:
Very Interesting topic is going on. I tried to down load the load shedding scheme through web site...
TG LOAD FLUCTUATIONS AND REVERSE POWER IN THE GENERATOR
New Replies:
Dear SKG,
I have few questions for your problem,
1) I hope the generator you are mentioning...
Coal Measurement methods
Steam turbine governor control swing
New Replies:
Dear Pichet,
In my earlier reply sticky operation of governor valve was also one of the reason...
Dear Pitchet,
There are two basic reasons for governor hunting,
1) Due to oil contamination...
Dear Pitchet,
To further understand your problem you may have to clarify following queries,
...
In a new CFBC boiler we are facing economiser tube failure frequently
New Replies:
> the "dent" is claimed to be on the external surface as if the tube tried to
>...
high vibration during normal running condition of steam turbine
New Replies:
The possible reasons for the only generator Vibrations are,
1) Check the oil flow to the...
Steam Turbine Non Active side Thrust Bearing Temp Going High
New Replies:
Dear Jojo,
Thanks for your elaborated response, first to your two questions,
1) There is no...
STG Parallel operation with other STG sets with finite bus
Select Page: 1
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2013 Nerds in Control, LLC. All rights reserved.