Control.com member...
Member Information and Posts by romrod
from the OIU department...
Bailey net90 OIU troubles
Topic: Continuous process industries, DCS questions.
Originally posted by George on 6 November, 2009 - 12:24 pm
Two OIU's crashed at our facility and no matter what parts I throw at them, they won't come back.
New Replies:
Wow!! surprised that some old OIU's are still out there doing their jobs... I agree, check the...
from the I dont know department...
FactoryLink 8.0 client builder window control
Topic: Human-Machine Interface and SCADA.
Originally posted by DF on 14 July, 2009 - 10:48 am
Using FactoryLink 8.0 I need to have a window pop up in ClientBuilder when a specific tag goes to a true state.
New Replies:
You need to do it using Visual Basic for Applications that comes embedded in ClientBuilder. ...
from the Forum department...
sugar level analyzer
Topic: Sensor technologies.
Originally posted by Ali on 21 June, 2009 - 9:22 am
measuring or detecting sugar level
New Replies:
very interesting discussion on how to measure brix. but what everybody uses is a conductivity meter...
what we do here in Venezuela is measure the conductivity of the solution... if it is too high then...
from the Automation List department...
Effects of increased load on generator without governor
Topic: Engineering and workplace issues.
Originally posted by electrics on 12 June, 2009 - 6:49 pm
What happens when you increase the load on a generator without a governor?
New Replies:
the energy equation will always balance... energy out will always be equal energy in. No paradox at...
Topic: PLCs and related questions.
Originally posted by Nandkishor on 14 April, 2009 - 3:19 am
Need IEC 61131-3 Compliant software for making ARM base PLC.
New Replies:
check http://www.isagraf.com/ they have embedded solutions and the complete family of...
from the Different versions of Modbus? department...
Modbus RTU on ABB AC250
Topic: PLCs and related questions.
Originally posted by Laban on 2 April, 2009 - 8:11 am
Are there different dialects of Modbus?
New Replies:
I have used MBRead/MBConnect with a variety of different modbus devices without any problem (SEPAM,...
from the Process Automation department...
Bailey Infi90 System
Topic: Continuous process industries, DCS questions.
Originally posted by Harsha on 20 March, 2009 - 6:10 am
Limitations of Bailey Infi90 System.
New Replies:
Wow, you have a very old INFI90 system. There have been new enhancements in the communication...
from the Automation List department...
PLC to VB - How to handle PLC data With VB
Topic: Programming languages.
Originally posted by syiqin on 22 February, 2009 - 10:29 pm
How to handle PLC data With VB
New Replies:
Python is free software, take a look: http://openopc.sourceforge.net/ a lot better than using...
from the Maintenance department...
Tenore NT Software
Topic: Software, including programming, OS issues, etc.
Originally posted by Yazid on 7 February, 2009 - 9:44 am
ABB Symphony System platform, Tenore NT software
New Replies:
Yes, I think Tenore NT was developed by Elsag Bailey in Italy. ABB support should be able to help...
from the Forum department...
OPC interfacing for Infi90
Topic: Software, including programming, OS issues, etc.
Originally posted by sha on 2 February, 2009 - 4:08 pm
Infi90 basics
New Replies:
CIU04, ICI, etc. are the hardware modules you need to get access to the INFI-NET, which is the high...
from the Automation List department...
How to configure USB port in Visual Basic
Topic: Programming languages.
Originally posted by venkat on 15 October, 2005 - 3:32 pm
How can I configure USB port in VB
New Replies:
I would use Python and PyUSB instead. Romulo Rodriguez...
1
 
 
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2009 Nerds in Control, LLC. All rights reserved.