Member Login
member
passwd
remember me on
this computer.

- join now -
- forgot username or password? -

Jump to a Date

Sponsored Communities
Cool stuff
Select a topic of interest:
...and press:
Neat Stuff
Control.com Stuff

Visit our shop for nerds in control lifestyle products.

Fortune
One is not superior merely because one sees the world as odious.
-- Chateaubriand (1768-1848)
RSS Feed
RSS feed Use this link to get an RSS feed of the Control.com article flow, for private, non-commercial use only:
www.control.com/rss/
To get a personalized feed, become a member at no cost.
Select a Page Style
Select one of the following styles:
- BluFu
- Classic
(cookies required)
1
Control.com member...
Member Information and Posts by some_guy
from the Forum department...
Hart Pass Through & Mux..what are they??
Topic: Communications systems and equipment.
Originally posted by Tashar on 17 March, 2009 - 12:56 am
Hart Pass Through & Mux..what are they??
New Replies:
HART is a two-way interface to "smart" analog devices. Pass-thru simply means that...
from the Automation List department...
GE Mk VI interface to DCS on Modbus
Topic: Communications systems and equipment.
Originally posted by Anonymous on 29 October, 2006 - 2:02 pm
method of connecting a DCS system to GE Mk6 using Modbus serial...
New Replies:
There are two ways to do this. CIMPLICITY has a Modbus Slave, but so does TCI. The TCI Modbus...
from the Mark VIe department...
Mark VIe protocols
Topic: Communications systems and equipment.
Originally posted by gisaac on 15 January, 2009 - 12:39 pm
Does the new Mark VIe support DNP 3.0?
New Replies:
And no, the Mark VIe does NOT talk DNP 3.0. DNP 3.0 was developed by the Transmission and...
GE handles alarms and events outside EGD. They are time stamped to 1 ms, but you will not be able...
from the Control Systems department...
GE Mark-II control upgrading
Topic: Application Questions and Problems
Originally posted by IC_ENGR on 11 June, 2008 - 1:26 am
GE Mark-II control system upgrading with latest and reliable control system.
New Replies:
This is true, as far as it goes. But there are new control functions that can be programmed into...
Topic: Human-Machine Interface and SCADA.
Originally posted by Brad on 27 January, 2009 - 10:12 am
Need to write a point from Cimplicity ver 6.5 to the PLC. Point must be translated on the read (Point /12) and written (Point * 12).
New Replies:
Are you using CIMPLICITY Machine Edition, or CIMPLICITY HMI/SCADA (used to be Plant Edition)? ...
from the Engineering department...
Interfacing WW with PI over serial
Topic: Communications systems and equipment.
Originally posted by Steve Winter on 28 January, 2009 - 10:03 am
To meet NERC standards for non-routable protocols we are trying to replace an existing ethernet connection between Wonderware and OSIsoft PI with a non routable serial.
New Replies:
Making this work over a serial link would be a real science project. However, I do not believe...
from the Ancient technology department...
mystery RTU protocol
Topic: Application Questions and Problems
Posted by some_guy on 29 January, 2009 - 10:16 am
BBCSI protocol information
1
 
 
Your use of this site is subject to the terms and conditions set forth under Legal Notices and the Privacy Policy. Please read those terms and conditions carefully. Subject to the rights expressly reserved to others under Legal Notices, the content of this site and the compilation thereof is © 1999-2009 Nerds in Control, LLC. All rights reserved.

Users of this site are benefiting from open source technologies, including PHP, MySQL and Apache. Be happy.

Advertisement
Our Advertisers
Help keep our servers running...
Patronize our advertisers!