Dear All,
We are facing frequent Profibus failures with ET200S IM modules of Siemens. They are connected to a S7-400 CPU on a machine. When it fails, the BF and SF LEDs are flashing randomly, and there is no Profibus communication with the module anymore. Most of the time, we are able to make the module alive again by only disconnecting and connecting the power of the module. If this also does not help, then we are changing the module with a new one.
I also have one more observation, the faulty modules are always with the following MLFBN numbers:
6ES7151-1AA02-0AB0 or 6ES7151-1AA03-0AB0.
We also have new machines with 6ES7151-1AA04-0AB0, they still didn't create any problem. Can it be because of this version problem? Or is there any other problem and solution know for this issue? I am waiting for your valuable helps. Thanks and regards...
Canan
We are facing frequent Profibus failures with ET200S IM modules of Siemens. They are connected to a S7-400 CPU on a machine. When it fails, the BF and SF LEDs are flashing randomly, and there is no Profibus communication with the module anymore. Most of the time, we are able to make the module alive again by only disconnecting and connecting the power of the module. If this also does not help, then we are changing the module with a new one.