Based on your query, my assumption is that you will be using clean water for landscape irrigation.
Magnetic flowmeter is one of the best solutions for this application. However, for the large HDPE pipe sizes, you have some sizing issues to consider. Large HDPE pipes normally have thick walls, so you will need to choose a mag-flowmeter a few sizes smaller than the HDPE pipe size so that the inside diameters match each other. That means you will have to provide adapter spools. Adapter spools may have to be made of internal-coated carbon steel. You also need to provide isolating and bypass valves so you can remove the magflow tube for lab calibration if required.
If you use Ultrasonic flowmeter, consider using Clamp-on Transit-Time Flowmeter if you have clean bubble-free water. Clamp-on configuration eliminates the need for adapter spools and valves that mag-flowmeters need. The bigger the pipe size, the cheaper Ultrasonic becomes, compared to magnetic. For sensor probe selection, you have to check with the vendor the maximum thickness the Ultrasonic probe can handle and make sure it is within the thickness of your HDPE Pipe.
Magnetic Flowmeter product technology is more mature than Ultrasonic, and is generally more accurate at +/- 0.3% or better. Ultrasonic Accuracy is typically around +/-0.5% to 1.0%. If accuracy is not an issue, Clamp-on Ultrasonic flowmeter is well worth considering.
Magnetic flowmeter is one of the best solutions for this application. However, for the large HDPE pipe sizes, you have some sizing issues to consider. Large HDPE pipes normally have thick walls, so you will need to choose a mag-flowmeter a few sizes smaller than the HDPE pipe size so that the inside diameters match each other. That means you will have to provide adapter spools. Adapter spools may have to be made of internal-coated carbon steel. You also need to provide isolating and bypass valves so you can remove the magflow tube for lab calibration if required.
If you use Ultrasonic flowmeter, consider using Clamp-on Transit-Time Flowmeter if you have clean bubble-free water. Clamp-on configuration eliminates the need for adapter spools and valves that mag-flowmeters need. The bigger the pipe size, the cheaper Ultrasonic becomes, compared to magnetic. For sensor probe selection, you have to check with the vendor the maximum thickness the Ultrasonic probe can handle and make sure it is within the thickness of your HDPE Pipe.
Magnetic Flowmeter product technology is more mature than Ultrasonic, and is generally more accurate at +/- 0.3% or better. Ultrasonic Accuracy is typically around +/-0.5% to 1.0%. If accuracy is not an issue, Clamp-on Ultrasonic flowmeter is well worth considering.